Parametric Study of an Autoclave Test for Nodular Corrosion /

The use of a steam corrosion autoclave test as a quality control tool for Zircaloy products has been practiced for many years. The most common form of the test is exposure to steam at 672 K, 10.3 MPa (750°F, 1500 psi) for three days. Some years ago it was found that this test did not predict suscept...

Full description

Bibliographic Details
Main Author: Schemel, JH (Author)
Corporate Authors: ASTM International, American Society for Testing and Materials
Format: Book
Language:English
Published: West Conshohocken, Pa. : ASTM International, 1987
Subjects:
Description
Summary:The use of a steam corrosion autoclave test as a quality control tool for Zircaloy products has been practiced for many years. The most common form of the test is exposure to steam at 672 K, 10.3 MPa (750°F, 1500 psi) for three days. Some years ago it was found that this test did not predict susceptibility to the occurrence nodular corrosion in boiling water reactors (BWR). A number of investigators found that a test at 723 to 773 K would produce nodular corrosion on Zircaloy products and therefore used the test as an index for research work on Zircaloy materials. More recently the test has been proposed as a quality control test on each lot of material. This study of test parameters and interlaboratory variability was undertaken as a necessary part of establishing an ASTM standard for such a test. Temperature of the test was found to be the most significant variable studied, and interlaboratory variation was relatively high when compared with the common 672 K test
Physical Description:1 online resource (14 pages) : illustrations, figures, tables
Bibliography:Includes bibliographical references